Programming Model
http://www.mcg.mot.com/literature 3-61
3
DPE_DP DPE_DP is the value that was on the DP0-DP7 signals
when the dpelog
bit was set.
dpe_ckall
When dpe_ckall is set, the Hawk checks data parity on all
cycles in which TA_ is asserted. When dpe_ckall
is
cleared, the Hawk checks data parity on cycles when TA_
is asserted only during writes to the Hawk.
Note that the Hawk does not check parity during cycles in
which there is a qualified ARTRY_ at the same time as the
TA _
dpe_me
When dpe_me is set, the transition of the dpelog bit from
false to true causes the Hawk to pulse its machine check
interrupt request pin (MCHK0_) true. When dpe_me
is
cleared, the Hawk does not assert its MCHK0_ pin based
on the dpelog
bit.
GWDP
The GWDP0-GWDP7 bits are used to invert the value
that is driven onto DP0-DP7 respectively during reads to
the Hawk. This allows test software to generate wrong
(even) parity on selected byte lanes. For example, to
create a parity error on DH24-DH31 and DP3 during
Hawk reads, software should set GWDP3.
Data Parity Error Address Register
DPE_A DPE_A is the address of the last PPC60x data bus parity
error that was logged by the Hawk. It is updated only
when dpelog
goes from 0 to 1.
ADDRESS
$FEF80070
BIT
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
NAME
DPE_A
OPERATION
READ ONLY
RESET
0 PL