10 - 6 WiNG CLI Reference Guide
dos-eapol-logoff-storm
[threshold [eapol-start-frames-
ap|eapol-start-frames-mu]<0-
65535> |trigger-against
{neighboring|sanctioned|unsa
nctioned}]
Detects DoS EAPoL Logoff Storm
threshold – Configures the event threshold
eapol-start-frames-ap <0-65535> –Detects EAPoL start frames
transmitted by an AP
eapol-start-frames-mu <0-65535> – Detects EAPoL start frames
transmitted by a client
<0-65535> – Select a threshold value between 0 and 65535
trigger-against{neighboring|sanctioned|unsanctioned} – Sets the
trigger from the list
neighboring – Triggers against neighboring ignored) devices
sanctioned – Triggers against sanctioned (approved) devices
unsanctioned – Triggers against unsanctioned (unapproved)
devices
probe-response-flood
[threshold probe-rsp-frames-
count <0-65535>|trigger-
against {neighboring|
sanctioned|unsanctioned}]
Detects Probe Response Flood values
threshold probe-rsp-frames-count <0-65535> – Configures the event
threshold
probe-rsp-frames-count <0-65535> – Count for probe response
frames transmitted by an AP
<0-65535> – Select a threshold value between 0 and 65535
trigger-against{neighboring|sanctioned|unsanctioned} – Sets the
trigger from the list
neighboring – Triggers against neighboring (ignored) devices
sanctioned – Triggers against sanctioned (approved) devices
unsanctioned – Triggers against unsanctioned (unapproved)
devices