Motorola MP6000 Spezifikationen Seite 135

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 200
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 134
SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 11
While performing a shift test, the indication of each position is within the applicable tolerance and the range of
results obtained should not exceed twice the applicable tolerance.
Audit Tallies
Audit Tallies (calibration counter = C, legal parameter counter = P) used for scale verification can be shown on
the Scale Display, or the 7-segment display.
1. Press and hold the Scale Zero button for three seconds to access the calibration tallies (not within
Calibration mode).
a. C### and P### tallies blink on the Scale Display and/or scroll on the 7-segment display.
i. C### represents the number of times the scale reached Calibration Success on page 4-7. (Only
successful calibrations are counted.)
ii. The P### represents the number of times any sealable parameter, or legal parameter was
changed with or without reaching Calibration Success on page 4-7.
2. When the Scale Zero button is released, the scale returns to normal operation, and the tallies are removed
from both displays.
IMPORTANT After verification, record/report audit trail information to the local Weights and Measure authority
where required by law.
NOTE 1. This feature is inhibited when the unit is in a scale Calibration Mode.
NOTE 2. If units of weight measure was modified (i.e., kg to lb, or lb to kg) the parameter counter is
incremented by two in the audit tally. This is because the Automatic Zero Setting legal parameter
is being enabled when going from lb to kg, and disabled when going from kg to lb.
Seitenansicht 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 199 200

Kommentare zu diesen Handbüchern