3 - 32 MP6000 INTEGRATOR GUIDE
ii. Medium MP6000 and short (shelf mount) MP6000: If the platter is not flush, or the MP6000 rocks,
adjust the optional leveling screws to place the device at the correct height. This can be done from
the top of the MP6000, with the tower bezel removed and the tower cover slightly pushed back.
Figure 3-41
Adjusting Leveling Screws
When the platter is flush, its leading edge should be slightly below the checkstand, and the trailing
edge should be slightly above the checkstand.
To ensure smooth scanning, replace the platter, take a steel can (like a soup can), turn it over so
the harsher seam is facing down, and slide the can over the platter in the standard scanning
direction. The can must not catch on the checkstand or the platter when swept across all sections
of the platter, in the correct direction.
4. Route all cables through the checkstand as shown in Figure 3-3
.
5. Connect all cables to the MP6000 and POS, as needed (e.g., scale, Scale Display, Checkpoint antennas,
or Sensormatic coils, POS, CSS, etc.).
6. Power up the MP6000. Upon power up, the MP6000 verifies that all sub-systems, and auxiliary devices
are operational. If a fault condition exists, an error condition displays on the 7-segment display, and the
startup sequence halts. Power cycling is required after rectifying the problem. (See General Error and
Warning Codes on page A-5)
If a scale is present, warm-up time for the scale is 15 minutes (assuming room the temperature is
70° F/20° C).
Leveling Screw Holes
Under Platter
IMPORTANT Leveling screws are an optional accessory for medium size models (15.7 in./39.8 cm) and short size
models (13.9 in./35.3 cm) and can be ordered separately. Accessory kit MX301-SR00004ZZWR
contains four standard-length screws, and accessory kit MX302-SR00004ZZWR contains four
extra-length screws which will protrude 1"-inch (25 mm) below the bottom of the unit. See Figure 1-5
on page 1-11 for the installation location of these screws and for the locations of access holes for
turning the screws from above.
IMPORTANT Most accessories (scale, Scale Display, Checkpoint interlock, Sensormatic coils, Sensormatic
RS-232 cable, CSS, and auxiliary RS-232 scanners) must be installed and connected to the
MP6000 prior to applying power to the MP6000.