Analog Output Module
36 of 56 ICD-13/05 ICD 13—Standard Controller
connector required for this socket is manufactured by Panduit, part number 120-332-
435E.
Testing of the 4100 card is limited by the simple interface which is presents to the pro-
grammer.
1. On power-up, the FAIL indicator is illuminated.
167-Bug>M FFFF4100
FFFF4100 0000? C100.
FAIL extinguished. This also confirms that the board responds to accesses from the
VMEbus, and enables the analog outputs onto the P3 connector.
TABLE 26. VMIC 4100 Switch and Jumper Settings
J/S Configures Setting
S2 1 A15 Closed
2A14 Open
3A13 Closed
4A12 Closed
5A11 Closed
6A10 Closed
7A9 Closed
8A8 Open
9A7 Closed
JB Supervisor Mode Access Out
JC 1 Async Updates, Ch 03 Out
2 Async Updates, Ch 47 Out
3 Async Updates, Ch 811 Out
4 Async Updates, Ch 1215 Out
5 Internal Update Trigger Out
TABLE 27. VMIC 4100 Switch S1
Card
#
Base
Address
S1
1234
0 4100 Closed Closed - -
1 4120 Open Closed Not
2 4140 Closed Open Used
3 4160 Open Open - -