Transition Module
10 of 56 ICD-13/05 ICD 13—Standard Controller
Install the VME enclosure in the desired workplace, generally a 19’ rack. If installed in
a rack the enclosure should rest upon two angle brackets mounted to the side rails of the
rack. Bolts should be installed in the front rails to secure the enclosure in the rack.
Optional telescopic rails are available from Elma but the enclosure does not have pre-
drilled holes for easy installation.
Check that the front power switch is off. Connect a grounded power cable to the rear
power outlet of the enclosure and to the external main power supply. The enclosure’s
power supply is capable of automatically detecting and switching between either 120
VAC/60 Hz or 240 VAC/50 Hz.
Turn on the front panel power switch. The cooling fans should start running. There are
no lights indicating the power supply is functioning. A qualified VME technician can
test the ±5 volt and ±12 volt DC power on the backplane using a VMEbus extender
card.
5.0 Transition Module
The transition module provides the I/O connections from the single board computer
through the backplane J2 socket. The connections are distributed to external devices
through a panel containing sockets for the various I/O devices.
5.1 Description
The Standard Controller transition modules are the Motorola MVME712-M.
TABLE 3. VME Enclosure Specifications
Item Description
Model Numbers - 12V-0920-RV21J12-P750-D
- 12V-0929-RV10/10J12-P750-D
Manufacturer Elma Electronic Inc.
Slots - 21
- 10/10
Dimensions 15.75” H x 17.0” W x 19.68” D
Output Power 750 W
Input Power Auto Ranging 90-132 V AC or 180-264 V AC
Frequency 47-65 Hz Automatically Selected
D/C Power 5V @ 120A, 12V @ 12A, -12V @ 8A
OperatingTemperature 0to50degreeC
Storage Temperature -30 to 85 degree C
Humidity 20 to 90% non-condensing
Cooling 3 fans @ 100 CFU each.