Synchro Bus Interface Card
ICD 13—Standard Controller ICD-13/05 19 of 56
In the above, XXXX can be any value, and the BCD digits HH and MMSS should be the
same as the time displayed at the moment the memory dump was done. There are no
more tests which can be performed without additional equipment or software, so
providing the memory dump matches and the time display increments correctly the
card should be assumed to be working satisfactorily.
8.0 Synchro Bus Interface Card
IOCs which require fast, deterministic communication with other IOCs using the Syn-
chro Bus will need a Reflective Memory card. At the Gemini telescopes all nodes will
be connected together in a single ring of fiber-optic cable[11]. For development pur-
poses where only a single node is available it is essential to connect the card’s fiber
transmitter to its receiver to obtain correct operation of the software.
8.1 Description
The Standard Controller Synchro Bus Interface cards is the VMIC
VMIVME-5588-000. It will be necessary to install a pair of bulkhead connectors on the
back panel of the VME crate and two short cables (1 meter should be sufficient, depend-
ing on the location
of the Reflective Memory card and the back panel connectors) from the card to these
connectors. Each card is supplied with a Product Manual [10] which describes the card
and its programming interface, card installation and set-up, VMIC’s warranty and repair
policy, and a complete parts list and circuit diagram.
A fiber cable assembly is needed to connect the reflective memory cards. The VMIC
VMICBL-000-F3-0xx fiber cable assembly can be obtained from VMIC at the same
time as buying the cards, using the above part number. The xx in the number should be
replaced by a length code obtained from the table below. These cables are U.L./NEC
rated OFNP and comprise a multi-mode single fiber with a 62.5 micron core and a 2.5
mm ST style bayonet connector on each end. The transmitters operate at 860 nm at 1
Gbaud, and the maximum attenuation between Reflective Memory nodes is 6 dB. Any
alternative cables should be equivalent to the above specification.
8.2 Installation
The reflective memory card is configured using a series of jumpers on both the mother
and daughter boards which make up the module. Jumper locations are shown in the dia-
gram on page 5-2 of the Product Manual, and should be set according to Table 13 on
page 20.
The Node ID jumpers E8 must be set uniquely for every Reflective Memory card on the
fiber ring. For development purposes where only a single node is available the setting
does not matter, but for the delivered hardware the Node ID will be specified by the
Gemini Software and Controls Group.
The VMIVME-5588 is a double-width module which only makes connections to one of