VME Single Board Computer
14 of 56 ICD-13/05 ICD 13—Standard Controller
The testing procedure is as follows:
1. Switch off the enclosure DC supply.
2. Remove the front panel.
3. Install the card in the left-most VME slot. Note that for the first few insertions it may
be quite hard to push cards completely home because the DIN41612 connectors are
new, but they should free up after about 3 or 4 insertion cycles. Make sure the two
retaining bolts on the card front panel are free before applying much force. Push
only against the card handles or the central front panel bolt, the remainder of the
front panel should not be stressed. The card is fully inserted when the front panel is
flush with the sides of the card cage.
4. When the card has been pushed home, the retaining bolts can be screwed home,
although during development it may be desirable to leave these loose to make the
card quicker to extract. Do not close the enclosure front panel while testing any of
the VME cards as it is useful to be able to see the various indicator LED’s which
appear on the card fronts.
5. Plug a terminal or computer which has terminal software into the transition module’s
console port. The connections for the cable to be used here depend on the device to
be used and the way in which the transition module jumpers have been set for the
particular port (see Section 5.2).
6. Set up the terminal for the following serial parameters: 9600 baud, 8 bits, 1 stop bit,
no parity, XON/XOFF or RTS/CTS flow control (XON/XOFF and 3-wire connec-
tions recommended).
7. Turn on the VME rack. The following should happen:
All MVME167 LED’s illuminate until the VMEbus RESET* line is released.
STAT, LAN, SCSI and VME LED’s extinguish, and the following should be dis-
played on the terminal:
Copyright Motorola Inc. 1988-1994, All Rights Reserved
MVME167 Debugger/Diagnostics Release Version 2.2 - 01/14/94
COLD Start
After a short pause:
Local Memory Found =01000000 (&16777216)
TABLE 7. MVME167 Jumper Settings
Jumper Setting Location
J1 1-2, 3-4, 5-6, 7-
8, 9-10, 11-12,
13-14, 15-16
Near LED’s
J2 1-2 Near LED’s
J6 2-3 Near P2
connector
J7 2-3 Near P2
connector