PC controls reset
Tick this box if the host PC is able to control the reset cycle on the target board.
Using DTR/RTS
Select whichever signal is used for the remote re-setting.
With +ve/-ve going pulse
Select the pulse polarity. For the avoidance of doubt about the meaning of RS232 'asserted', etc. the
descriptions +ve/-ve refer to the actual polarity of the pulse with respect to the common ground pin
(pin 5 on the DB9 connector). Note that most RS232 level shifter chips on target boards invert this
polarity, and also that RS232 line receivers usually bias their inputs so that a disconnected input
appears to be at a negative voltage.
Reset downtime
Time, in seconds, for the reset pulse to remain in the 'low' state. The minimum value is 0.1 s (100 ms),
and the maximum 999 s (16 min 39 sec - a long wait!). The important thing is that Vdd falls to within
100 mV of Vss to achieve a reliable reset. The default value is 0.1 seconds, but this may well be too
short - it all depends on the target board circuitry.
Remote Monitor/User Mode Switch
With the necessary logic hardware on the target board, the PC can be used to control whether the
MCU runs in Monitor mode, or executes its own user-written program; using whichever RS232 output
signal is not already being used by the remote reset function. See Monitor/User Mode Switching on
page 11 and Appendix B - Hardware for more details.
PC controls switching
Tick this box if the host PC is able to toggle the output.
Using:
Select whichever RS232 output pin is to control the switching. If DTR is selected then the labels in
this box will change to DTR rather than RTS.
General-purpose switch is 'ON' when RTS is positive/RTS is negative
Choose the pin voltage level which corresponds to the 'ON' state.
General
Note that changes made on this tab will cause the COM port to close (disconnect) if the Settings
dialog is closed by clicking the 'OK' button.