English Locomotive decoders 30s series
Page 26
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Acceleration
rate
3 44 0 ... 255
(LD-G-30: 20)
(LD-G-31: 16)
(LD-G-32: 20)
(LD-G-33: 16)
(LD-G-34: 16)
(LD-W-32: 16)
(LD-W-33: 10)
= Length of the delay before
the switching to the next
higher speed level when the
locomotive is accelerating.The
delay is calculated as follows:
(value of CV#3) x 0,9 sec. /
number of speed levels
Braking rate 4 45 0 ... 255
(LD-G-30: 15)
(LD-G-31: 8)
(LD-G-32: 15)
(LD-G-33: 8)
(LD-G-34: 8)
(LD-W-32: 5)
(LD-W-33: 5)
= Length of the delay before
the switching to the next
lower speed level when the
locomotive is braking. The
delay is calculated as
described in CV#3.
Maximum
voltage
5 46 0 ... 255
(0)
= The voltage to be output to
the motor at the highest speed
level. The value "2"
corresponds to 0,8 %, the
"255" to 100 % of the max.
voltage.
See "optimizing the driving
characteristics" at the end of
section 8., as well.