5
55
5-
--
-4
44
4 Operation
AT&T SLW2500 Installation and Operation Manual
SLW25-RPLR Return-Path Laser Receiver
The SLW25-RPLR is a return-path optical receiver used in the SLW2500 node platform. It is
used in conjunction with a Motorola AM-Blazer, AM-OMNI-LM*, AM-OMNI-ALM, MegaStar, or
other similar optical transmitter.
Figure 5-3 illustrates the SLW25-RPLR:
Figure 5-3
SLW25-RPLR
OPTI CAL
POWER
L
O
W
F
A
U
L
T
O
N
HYBRID
CURRENT
(1 V/A)
OPT ICAL
POWER
(1 V/mW)
N
O
R
M
H
I
G
H
Opt i cal Recei ve r
ASSEMBLED
IN MEX ICO
SLW25-RPLR
Tables 5-4 and 5-5 provide additional information on the user-related features and output levels
of the SLW25-RPLR:
Table 5-4
SLW25-RPLR features
Feature Description
Optical power test point This test point enables monitoring of the optical power level at the input to the
module. The nominal scale factor is 1.0 V/mW.
Hybrid current test point This test point enables monitoring the current drawn by the amplifier section
of the integrated optical receiver hybrid. The nominal scale factor is 1.0 V/A.
The hybrid current test-point voltage is between 0.150 V and 0.350 V (hybrid
current of 150 mA through 350 mA) when the module is enabled under
normal operating conditions.
Receiver enable A green LED that provides visual indication of the receiver’s enable status.
Fault indicator A red LED that illuminates when the module is enabled but the hybrid current
is outside the normal operating range.
Optical power status A green LED that is ON when the optical power is within the recommended
operating range (refer to Table A-4). Two red LEDs indicate that the optical
power is above (
HIGH) or below (LOW) the recommended optical input power
range.