Motorola SYMBOL MS320X Spezifikationen Seite 208

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 428
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 207
11 - 16 DS457 Fixed Mount Imager Integration Guide
OCR Template
Parameter # F1 23h
This option creates a template for precisely matching scanned OCR characters to a desired input format.
Carefully constructing an OCR template eliminates scanning errors.
To set or modify the OCR decode template, scan the OCR Template bar code, then bar codes corresponding
to numbers and letters on the following pages to form the template expression. Then scan End of Message.
The default is
54R which accepts any character OCR strings.
Required Digit (9)
Only a numeric character is allowed in this position.
Template Valid data Valid data Invalid data
99999 12987 30517 123AB
Required Alpha (A)
Only an alpha character is allowed in this position.
Template Valid data Valid data Invalid data
AAA ABC WXY 12F
OCR Template
End of Message
9
A
Seitenansicht 207
1 2 ... 203 204 205 206 207 208 209 210 211 212 213 ... 427 428

Kommentare zu diesen Handbüchern

Keine Kommentare