Motorola CPU32 Betriebsanweisung Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 107
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
To interpret the LEDs
The LEDs on the preprocessor interface hardware have meanings described
below, after the following has been done:
1. The ID switches have been set (described in previous section).
2. The preprocessor configuration has been downloaded.
LED Interpretations
LED DS1 - Default
This LED identifies the type of configuration loaded into the
reconstruction hardware. If the LED is lit, the default configuration is
loaded. If this LED is not lit, a custom configuration is loaded. This
LED only has meaning if LED DS2 is not lit.
LED DS2 - NO CONFIG
This LED indicates whether or not a configuration has been loaded
into the preprocessor interface. If it is lit, no configuration has been
loaded. If it is not lit, a configuration has been loaded.
LED DS3 - Reserved for future support of hardware breakpoints.
The illustration on the following page shows the HP E2480A LEDs.
If DS2 remains lit after power has been applied to the preprocessor, the
preprocessor contains an unknown reconstruction configuration. To resolve
this unknown state, cycle power to the preprocessor or execute a "pp load"
command (see next section).
Chapter 2: Hooking up Your System
To interpret the LEDs
2–32 E2480A Motorola CPU32 Preprocessor Interface