Chapter 2: Connecting the Emulation Probe to a LAN
Connecting the Emulation Probe to a LAN
Switch S5 should be set to OFF if you are connecting to the BNC
connector
Switch S5 should be set to ON if you are connecting to the 10BASE-T
connector.
Set all other switches to ON.
5
Connect the power cord to the emulation probe.
6
Verify that the power light stays on after 10 seconds.
The IP address will be stored in EEPROM.
7
Set switch S6 back to ON.
Do this so that the emulation probe does not request its IP address
each time power is cycled. The IP address is stored in EEPROM, so
BOOTP does not need to be run again. Leaving this switch on will
result in slower performance, increased LAN traffic, and even failure to
power up (if the BOOTP server becomes inactive).
8
Verify your emulation probe is now active and on the network.
See "To verify LAN communications" on page 41.
See Also
For additional information about using bootpd, refer to the
bootpd (1M) man page.