Installation Guide 19
1.10.4 AP 7161 Grounding Screw
The grounding screw is located to the right of the GE1/POE port and above the GND symbol.
The grounding cable can be attached to the unit using one of three recommended methods. Using an 8mm socket
and driver:
Loosen the grounding screw and insert the grounding cable into the hole below it. Tighten the grounding
screw to 30 inch pounds (lbf-in).
Loosen the grounding screw and wind the grounding cable around the screw. Tighten the grounding screw
to 30 inch pounds (lbf-in).
Attach a ring lug to the grounding cable and remove the grounding screw to attach the ring lug to the
Access Point. Secure it to the unit by reinserting the grounding screw. Tighten the grounding screw to 30
inch pounds (lbf-in).
WARNING! The grounding cable for an AP 7161 must be at a minimum a #10 gauge wire cross
section.