Motorola Axiom CMD11E1 Betriebsanweisung Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 101
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
3.10. HARDWARE INTERFACING 47
3
3.3K
LED
To ground
To test point
PA5 for example
Figure 3.1: Test Probe. Make sure that the resistor is connected to the anode of
the light emitting diode. The longer lead of the light emitting diode is the anode.
To test a pin, connect the cathode to ground and the resistor to the pin.
5V (pin 9 or 10)
4.7K
22K
PA0 (pin 1)
Ground (pin 11 or 12)
Switch
Figure 3.2: Typical input connection
6. Connect a (RIGHT) test probe between pin 6 and pin 12. The cathode of
the light emitting diode should be connected to pin 12 and the free end of
the resistor to pin 6.
7. Label the two light emitting diodes as LEFT and RIGHT so that it is easy
to identify them (you can use a magic tape and small pieces of paper).
8. Connect the input circuit as shown in figure 3.2.
9. Check and recheck all your connections before you connect the power to the
HC11.
Special instructions for FOX11 users
1. Connect two LED circuits shown in figure 3.1 to PA4 and PA5. Label the
circuit connected to PA4 LEFT and the one connected to PA5 as RIGHT.