Telit G30 has an internal optional SIM chip and external interface to SIM connector same as G24-L. In addition G30 module supports: When exter
Differences in the audio output and input gain settings between G24-L and G30 may be noticed. Different gain levels for each path need to be se
Turning OFF Using ON_N: G24-L: Asserting the ON_N signal low for a minimum of 2 seconds. G30: Asserting the ON_N signal low for a minimum of 3 s
The following table describes the differences between the G24-L and G30 interface connector signals. Signals marked in color red have changed b
Connector Pin # G30 G24-L Differences 34 GPIO4/SCL GPIO4 35 36 GPIO5 GPIO5 37 ADC1 ADC1 38 GPIO6 GPIO6 39 40 GPIO7 GPIO7 41 ANT_DET
The mechanical design is similar between G24-L and G30. The differences in the modules are in connectors and height, as described below. G24-
The following table is providing a full overview on software features differences between G24-L and G30 modules. To use commands that are equal
AT Commands – Removed EGPRS EGPRS commands removed (CGEQREQ,CGEQMIN,CGEQNEG,CEG) +MEGA Email Gateway Address Removed STK Motorola commands r
+MEMW Removed +MFS Frequency of Search – Not supported +MTDTR DTR line – Not supported +MTCTS CTS line – Not supported +MMAR Removed +EMPC
AT Commands – Updated +MMICG Range supported is 0-15 ATI[n] Updated +CRTT 16 Ring Tones instead of 41 Character Set Replace ASCII with IRA.
S register S6, S8 and S18, assed +MIPCONF The parameters: <keep_alive_timeout>, <keepalive_interval>, <keepalive_probes>, rem
SMS When reading an incoming SM, the message header will be passed as usual. The DATA will be output in as received from NW without any conver
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Notice While reasonable efforts have been made to assure the accuracy of this docume
Usage and Disclosure Restrictions License Agreements The software described in this document is the property of Telit and its licen
The purpose of this document is to provide G24-L customers with a general overview of the electrical and programming interface differences
Danger – This information MUST be followed or catastrophic equipment failure or bodily injury may occur. Caution or Warning – Alerts the u
The G30 GSM/GPRS module is available on a LGA 81-pin form factor, and with a 70 pin connector as well, maintaining the same mounting design as
Telit G30 module was designed with regards to electrical, mechanical and software compatibility to G24-L module. The following is delta within